beautypg.com

Figure 7-1, Configuring the console port, Console port settings 7-2 – Accton Technology ES4524D User Manual

Page 90

background image

Console Port Settings

7-2

7

Web – Click System, Line, Console. Specify the console port connection parameters
as required, then click Apply.

Figure 7-1 Configuring the Console Port

CLI – Enter Line Configuration mode for the console, then specify the connection
parameters as required. To display the current console port settings, use the show
line
command from the Normal Exec level.

Console(config)#line console

36-1

Console(config-line)#login local

36-2

Console(config-line)#password 0 secret

36-3

Console(config-line)#timeout login response 0

36-4

Console(config-line)#exec-timeout 0

36-4

Console(config-line)#password-thresh 5

36-5

Console(config-line)#silent-time 60

36-6

Console(config-line)#databits 8

36-6

Console(config-line)#parity none

36-7

Console(config-line)#speed auto

36-8

Console(config-line)#stopbits 1

36-8

Console(config-line)#end
Console#show line console

36-9

Console configuration:
Password threshold: 5 times
Interactive timeout: Disabled
Login timeout: Disabled
Silent time: 60
Baudrate: auto
Databits: 8
Parity: none
Stopbits: 1
Console#

This manual is related to the following products: