Logging trap – Accton Technology ES4524D User Manual
Page 322
Event Logging Commands
37-4
37
Command Usage
The command specifies the facility type tag sent in syslog messages. (See
RFC 3164.) This type has no effect on the kind of messages reported by the
switch. However, it may be used by the syslog server to sort messages or to
store messages in the corresponding database.
Example
logging trap
This command enables the logging of system messages to a remote server, or
limits the syslog messages saved to a remote server based on severity. Use this
command without a specified level to enable remote logging. Use the no form to
disable remote logging.
Syntax
logging trap [level]
no logging trap
level - One of the syslog severity levels listed in the table on page 37-2.
Messages sent include the selected level up through level 0.
Default Setting
• Disabled
• Level 7 - 0
Command Mode
Global Configuration
Command Usage
• Using this command with a specified level enables remote logging and sets
the minimum severity level to be saved.
• Using this command without a specified level also enables remote logging, but
restores the minimum severity level to the default.
Example
Console(config)#logging facility 19
Console(config)#
Console(config)#logging trap 4
Console(config)#