I/o menu descriptions, continued, Zero – Fairbanks 2800 Series Intrinsically Safe Instrument User Manual
Page 45

Section 3: Programming
01/12
45
50647 Rev. 9
3.5.1. I/O MENU DESCRIPTIONS, CONTINUED
PROMPT
CHOICE(S)
SPALrt
Used
for
ALARM
purposes.
In
the
SoLo
mode
only Relay 8 is used, for both the LOW and HIGH
alarm.
In the paired mode, Relays 4 and 8 are used.
The setpoint-relay will be active when the GROSS weight is equal to or
below the programmed LOW ALARM weight value or equal to or
above the programmed HIGH ALARM weight value.
─ The following applies to either of the Setpoint Batch modes, whenever the
weight on the scale is below or above the Alert Value, and the Alert is
enabled
. The alert relay(s) toggle On/Off when the following occurs.
The front panel keys are pressed.
The instrument comes out of its Sleep mode.
The
SPALrt
targets are only programmable in the IO Port B Menu.
The
SPALrt
may be used with all other setpoint modes except whenever
four (4)
paired setpoints are programmed.
If
SPALrt
is enables in conjunction with any other setpoint option, the
instrument prompts for Alarm low wgt, causing an Alarm high wgt.
Alarm IO
must be set to a value other than
zero.