beautypg.com

Aiphone GH SERIES 0207 AIC User Manual

Page 7

background image

- 7 -

1-2

Expanded System Configuration Diagram

1. Common trunk line #1, 2
2. Sub trunk line #1 - 4

Sub trunk line #2 - #4 are the same as #1. Maximum 125 units

per sub trunk line.

(1) Audio signal line
(2) Video signal line
(3) Power supply line

a. Entrance station (For details, see 2-1 and 2-2)
b. Bus control unit
c. Residential station (For details, see 2-4):

Station-to-station wiring (For details, see 1-1)

d. Residential station (For details, see 2-4):

Homerun wiring (For details, see 1-1)

Do not mix station-to-station wiring and homerun wiring on a
single trunk line.

e. Security Guard Station
f. Expanded Bus control unit
[1] Expanded video Bus control unit GH-VBX
[2] Expanded Bus control unit GH-BCX/A
[3] Distribution terminal (junction): Not included
[4] Power supply PS-2410LC, PS-2410LD, PS-2410DIN

1-3

Wiring Distance

∗ DP = Distribution Point

Capacity

Entrance Station

Maximum 16 stations
(up to 3 stations per trunk)

Residential stations
per Sub trunk line

Maximum 125 stations
(up to 25 stations per trunk)

Residential Station

Maximum 500 stations

Security Guard Station

Maximum 4 stations

Residential stations
in the same residence

Maximum 4 stations
(up to 2 monitor stations)

Bus control unit
per Common trunk line

Maximum 1 unit

Bus control unit
per Sub trunk line

Maximum 1 unit

Diameter of wires

0.65 mm

(22 AWG)

0.8 mm

(20 AWG)

1.0 mm

(18 AWG)

GH-BC - DP

DP - GH-DA/A

GH-VBC - GH-VA

GH-MK - DP

DP - farthest residential station
(R1-R2)
(Includes system with GH-4Z)

GH-VBC - farthest residential station
(1 monitor unit/residence)
(Includes system with GH-4Z)

GH-VBC - farthest residential station
(2 monitor units/residence)
(Includes system with GH-4Z)
GH-VBC (SW: STD)
- GH-VBC (SW: EXP)
GH-BC - power supply

GH-VBC - power supply

GH-NS - power supply

GH-MK - power supply

5 m

(16')

5 m

(16')

5 m

(16')

300 m

(980')

300 m

(980')

300 m

(980')

300 m

(980')

300 m

(980')

300 m

(980')

5 m

(16')

5 m

(16')

300 m

(980')

300 m

(980')

150 m

(500')

150 m

(500')

100 m

(330')

-

-

GH-BCX/A - power supply

5 m

(16')

5 m

(16')

-

-

-

150 m

(490')

-

-

-

-

100 m

(330')

100 m

(330')

50 m

(165')

-

-

-

-

-

2500 m

(8200')

-

-

300 m

(980')

-

-

150 m

(500')

-

-

300 m

(980')

-

-

300 m

(980')

-

-

300 m

(980')

150 m

(500')

-

-

-

150 m

(500')

100 m

(330')

-

150 m

(500')

100 m

(330')

50 m

(165')

150 m

(500')

Standard system
total wiring distance

each

2500 m

(8200')

-

-

each

2500 m

(8200')

-

-

Expanded system
total per Common trunk line
(maximum 2 trunk lines)

Expanded system
total per Sub trunk line
(maximum 4 trunk lines)

GH-BC - GH-BCX/A

GH-VBC - GH-VBX

GH-DA/A - GH-BCX/A

GH-VA - GH-VBX

GH-BCX/A - farthest residential station
(R1-R2)
(Includes system with GH-4Z)
GH-VBX - farthest residential station
(1 monitor unit/residence)
(Includes system with GH-4Z)
GH-VBX - farthest residential station
(2 monitor units/residence)
(Includes system with GH-4Z)