beautypg.com

Aiphone GH SERIES 0207 AIC User Manual

Page 37

background image

- 37 -

9-2

Program Mode (GH-MK)

1. Menu 1: Select language

Choose language to be displayed on GH-MK.

2. Menu 2: Change ID code

Enter new ID code starting with "

∗", then 4-digit number.

(Example:

∗1234)

3. Menu 3: Write in resident information

Register room #s and resident names.
Enter room #s using 1 to 6-digit characters.
Enter resident name (up to 16 characters).

4. Menu 4: Set input timeout timer

Operation Timer: If the operation panel is not operated for a
certain period of time, the system returns to standby mode.
Programmable from 15 to 99 seconds.
Program Timer: If, in Resident Programming mode, the
operation panel is not operated for a certain period of time, it
automatically cancels the programming mode. Programmable
from 30 to 99 seconds.
Call Time: Call from Entrance panel expires in a certain period
of time. Programmable from 30 to 99 seconds.

5. Menu 5: Programming
∗ For the programming procedures, see 9-1.
6. Menu 6: Transfer link information

With Expanded System, enter unit ID# for transferring

Entrance stations and Security guard stations as below;

• Entrance station: Connected to same common line -

"programmed ID#" as is. (e.g. transferring to #2: Enter "2"), or

Connected to another common line - "programmed ID# plus
8" (e.g. transferring to #1: 1+8=9, Enter "9")

• Security guard station: Connected to same common line -

"programmed ID#" as is. (e.g. transferring to #2: Enter "2"), or

Connected to another common line - "programmed ID# plus
2" (e.g. #1: 1+2=3, Enter "3")

7. Menu 7: Link check (for maintenance purposes)
∗ An electronic sound will be emitted once if link is normal. If

the link is abnormal, an alarm sound will be emitted.