- INSTRUCTIONS -
The RY-24L Door Release Relay Module is an interface between the door release contact on the Aiphone monitor and the
actual release mechanism. The contact closure directly out of the monitor is rated at 12V AC with a low current capacity. If
your strike or maglock requires more voltage or current, the RY-24L is required. It provides either a Normally Open contact
for an electric strike, or a Normally Closed contact for a magnetic lock. The contact rating supports a majority of door
release hardware available on the market. The RY-24L relay is recommended with all AX, KC, KB, and JA video systems
when using the door release feature. This will protect the built-in contact from possible surge damage.
(Note: For more than one door release on the KB system, use the RY-3DL.)
RY-24L
Form C Door Release Relay for AX, KB, KC, and JA Color Video Systems
WIRING DIAGRAMS:
Page 1
INSTALLATION:
1. Install in a suitable location, either near the power source for the door release mechanism, or behind the monitor.
2. Secure wire connections with proper termination, such as wire nuts or crimp connectors.
3. Trim the wires to the desired length.
4. Trim the unused contact wire so the bare strands are not exposed.
RED: L/ORG
BLK: (-) Neg.
BRN: Common
ORG: N/O
YEL: N/C
RY-24L COLOR CODE:
Input of Relay:
Red:
L/ORG, Postive trigger
Black:
(-) NEGATIVE
Output of Relay:
Brown:
COMMON
Orange:
N/O Contact
Yellow:
N/C Contact
(See contact rating specs on
back page)
Connect RED and
YELLOW wire on
JA--2MCD/-2MECD
directly to +
A1
A2
JA-2MECD
JA-2MCD
B1
B2
A1
A2
Purp
Blu
Grn
Yel
Org
Red
Brn
L1 (Brn)
L1 (Red)
L2 (Org)
L2 (Yel)
#2
#1
PS-2420UL
+
-
Door 1
JA-DAC
A1
A2
C1
C2
C1
C2
D
O
O
R
1
S
U
B
D
O
O
R
2
A
D
A
P
T
E
R
1
A
D
A
P
T
E
R
2
Blk
Brn
Org
Yel
RY-24L
Red
LOCK
POWER
Door
Release
#1
Brn
Org
Yel
RY-24L
Door
Release
#2
Blk
Red
MAGNETIC LOCK
WIRING METHOD:
(Normally Closed contact)
+
-
LOCK
POWER
ELECTRIC STRIKE
WIRING METHOD:
(Normally Open contact)
Door 2
JA-DAC
A1
A2
COM
N/O
N/C
NOTE: The door release contacts are rated at 24V AC, 500mA. The RY-24L should be used in any application where the
strike or maglock has a higher voltage or draws more current. Otherwise, internal damage to the JA monitor could result.
JA System Wiring