beautypg.com

Aiphone GH SERIES 0207 AIC User Manual

Page 25

background image

- 25 -

Expanded System

1. Common trunk line: maximum of 2 trunk lines
2. Sub trunk line: maximum of 4 trunk lines

Maximum of 125 units (maximum of 48 units for standard
system)

• The wiring of the sub trunk line is the same as the standard

system. For details, see 4-1 to 4-3.

[1] Entrance Station
• Basic System #1 - #5
• Expanded System (#1 - #8) x 2

When installing multiple entrance stations, make sure to set
the GH-DA/A ID numbers (SW2).

[2] Security guard station GH-MK
• Standard System #1, #2
• Expanded System (#1, #2) x 2

When installing plural security guard stations, make sure to
set the ID numbers (SW1).

[3] Expanded video Bus control unit GH-VBX

Connector cable length: 40 cm (15-3/4")

[4] Expanded Bus control unit GH-BCX/A

For connecting the lift control adaptor GHW-LC, refer to the
GHW-LC Installation & Operation Manual.

[5] Bus control unit GH-BC
[6] Distribution terminal (junction): not included
[7] Power supply PS-2410LC, PS-2410LD, PS-2410DIN

NP: Non-polarized

NOTE: For communication between Entrance station and

Residential station, one each communication path is
available to "COMMON1 - SUB1" and "COMMON2 -
SUB2". In case of crossover communication such as

"COMMON1 - SUB2" or "COMMON2 - SUB1", it

occupies entire communication path in the system.

4-4

4-5

External Signaling Relay Connection

[1] Input wire (blue)
[2] Input wire (white)
[3] Output wire (orange)
[4] Output wire (orange)
[5] Timer (not included)
[6] Buzzer
[7] Entrance light
• GH-RY contact specifications: AC/DC 24 V, 0.5 A ([3], [4])

When connecting GH-RY to GH-1AD, GH-1KD, GH-1MD or
GH-MK, the separate option connector is required.
Please consult your AIPHONE Distributor.

[2]

[1]

[4]

[3]

[5]

AC

B

GH-RY

[6]

[7]