beautypg.com

Dixon Valve 25 TON RAM Complete Manual User Manual

Page 62

background image

25 Ton Ram Instruction Manual

Internally Expanded Steel & Stainless Steel Stems

customer service

800

355

1991

1

Section 6

(refer to

Converting Swaging to Expansion section).

Before you begin make sure the ram is fully
retracted. Select the proper Pull Rod.

• For 1” thru 1 1/2” use Part Number

25RODSMALL

• For 2” thru 4” use Part Number

25RODLARGE

(note that picture is showing

25RODLARGE)

Screw the short threaded end of the rod into the face
plate of the

25IXATTACH.

Select the corresponding Adapter Plate (s) for the
size and type of fitting you are installing.

The 2” thru 4” adapters have two recesses. The small
diameter recess is to be used with stems having NPT*,
Victaulic or a plain end. The larger diameter recess is
used for stems with the “Heavy Duty/California Style”
end.

* See note on page 4.

Assuring that the recesses are facing outward towards
the operator, slide the adapter plate over the pull rod
until it reaches the base of the

25IXATTACH.

Tighten the set screws to secure the adapter.

Lubricate the I.D. of the stem with Crisco®
(recommended) or a high viscosity oil or
heavy duty grease.

3

2

4a

1