beautypg.com

Dixon Valve 25 TON RAM Complete Manual User Manual

Page 48

background image

1/00

5

Dixon Valve & Coupling Co., Call 1-800-355-1991

12

Lift the hose assembly up and remove the
pusher, spacer ring and die halves from the
die bed. Remove excess lubricant.

Note: If gauge reads 10,000 PSI before
swaging is complete, than the ferrule or die
used for that hose end may be incorrect.
Contact Dixon for further assistance.

Dixon Valve and Coupling Company recommends that all

hose assemblies be tested as recommended by the Rubber Manufacturers Association.

Pushers for RSTxxxNOS Stems

Size

Part Number

1 1/2”

2”
3”

RE150PUSH

D011-018

RE300PUSH