Maintenance and Care

5.5.1 Filling the solution tank
Fill the solution tank (Fig. 16/1) before
starting work or as necessary.

The solution temperature must
not exceed 50 °C!

1. Switch off the machine using the

main switch and disconnect the bat-
tery plug.

2. Open the housing cover and remove

the solution tank (Fig. 16/1).

3. Fill fresh water up to the marking, ap-

prox. 10 liters (add a cleaning agent
if necessary).

4. Reinstall the solution tank.

Observe the applicable laws
and local regulations when dis-
posing of cleaning agents!

5.5.2 Cleaning the solution filter
Check the solution filter (Fig. 16/2) daily
and clean or change it as necessary.
1. Switch off the machine using the

main switch and disconnect the bat-
tery plug.

2. Open the housing cover and discon-

nect the solution filter (Fig. 16/2)
from the hose.

3. Rinse the solution filter with water or,

if necessary, install a new one.

5.5.3 Check the seal
Check the solution tank seal (Fig. 16/3)
weekly and clean or change as neces-
sary.
1. Switch off the machine using the

main switch and disconnect the bat-
tery plug.

2. Open the housing cover and remove

the seal (Fig. 16/3) from the housing
cover.

3. Clean the seal and reinstall it or in-

sert a new one.