Maintenance and Care

5.4.4 Servicing the driving batteries
For information on servicing driving bat-
teries, refer to operating manual 88-60-
2556.

5.4.5 Removing the batteries
1. Park the machine on a level area of

floor.

2. Switch the Port A Scrub off at the

main switch.

3. Disassemble the Power Pack from

the Port A Scrub, refer to Section
2.7.

4. Loosen the four screws (Fig. 15/1)

and lift the cover (Fig. 15/2) off.

5. Remove the battery connection ca-

bles.

6. Remove the batteries.

5.4.6 Inserting the batteries
1. Install the batteries in the Power

Pack.

2. Connect the battery poles in accor-

dance with the connection plan (Fig.
15/3) using the connection cables.
Ensure they are connected firmly.

3. Replace the cover (Fig. 15/2) and

secure in place with the screws.

5.4.7 Disposing of batteries
Used batteries with the recycling sym-
bol contain reusable commodities. In
accordance with symbol with the
crossed out bin, these batteries must
not be disposed of in domestic waste.
Return and recycling must be agreed
on with a Minuteman authorized dealer.

in

accordance with § 8 BattV (Battery Di-
rective)!

Fig.15

1

2

3