On the inside of the flush tank the there are two (2) connections to the flush pump.
• The pump inlet air tube connects to the inlet side of the SP4 solvent pump
through the inlet fitting.
• The Yellow flush tube from the injection gun / mix head extends down
through the outlet side fitting and connects to the outlet of the solvent pump.
Note: it is important that the solvent level in the tank be at no less then 1/3
full or so that there is 25mm (1”) of solvent above the SP4 solvent pump.
This will allow the SP4 solvent pump to properly refill with solvent after
each use.
Maintenance – The SP4 Solvent Pump is basically maintenance free however it
might be necessary to replace the O-ring (0464) on the Pump Foot Valve (4481).
It is important to keep the inside of the flush tank clean and free of dirt, debris
and glass fiber as these can prevent the Pump Foot valve from sealing properly.