FIRST TIME START-UP CHECK LIST

INNOVATOR MEGAJECT


ACTIVITIES MUST BE DONE IN THE SEQUENCE SHOWN, AND MUST BE TICKED
OFF AS COMPLETED. THIS SEQUENCE FOLLOWS ON FROM “PRE-START
CHECKLIST INNOVATOR MEGAJECT”



ACTIVIT

Y NO.

ACTIVITY

TICK
WHEN
COMPLET
ED

Priority

Put on Respirator as specified for spray painting, Protective
Clothing, Eye Protection, and PVC Gloves

1

Turn the pump regulator to zero

2

Adjust the catalyst percentage required with the slide arm Knob.

3

With all the material containers properly filled. Press the
Recirculation Button on the control panel.

4

Slowly increase the pump regulator so that the pump strokes
slowly and evenly.

5

Allow the pump to recirculate until the flow of Resin and Catalyst
back to there respective containers is free of bubbles.

6

Press the Stop button to take the unit out of recirculation mode

7

Test the catalyst and resin to the Injection head – Place a
suitable container under the injection head and press the Inject
button. After 4 or 5 strokes press the Stop button.

8

Check that the material properly cures

9

Properly dispose of the catalyst and resin.

10

Flush the Injection head as necessary into the appropriate
container.


ABNORMAL CONDITIONS OBSERVED AND CORRECTED

Abnormal Condition

a

a

a

a when

corrected


OPERATORS NAME

________________________________

DATE:

____________

SIGN OFF WHEN START UP CHECKS ARE COMPLETED:

_______________________