PRE-START CHECKLIST
INNOVATOR MEGAJECT
ACTIVITIES MUST BE DONE IN THE SEQUENCE SHOWN, AND MUST BE TICKED
OFF AS COMPLETED.
ACTIVIT
Y NO.
ACTIVITY
TICK WHEN
COMPLETED
Priority
Put on Respirator as specified for spray painting,
Protective Clothing, Eye Protection, and PVC Gloves
1
Have all Tools and materials available for pre-start checks.
2
Connect the 6mm air line to the to the air supply.
3
Slide the air valve on the back of the cabinet to OPEN position.
4
Twist & Pump E-Stop to allow machine operation
5
Check all catalyst & resin fitting to be sure they are tight
6
Fill pump packing nut 1/3 full with PAT-LS-OIL.
7
Fill the Catalyst Jug at least 1/2 full of catalyst.
8
Secure the Pick-up wand to the pump inlet
9
Place the Resin Pick-up wand in the resin supply container.
10
Place the end of the Resin Return Hose in the resin container.
11
Fill the Solvent Flush Tank 3/4 full.
12
Place the appropriate container under the Injection Head and
Test the Flush system by pressing the Flush Button.
THE UNIT IS NOW READY TO BE STARTED UP. GO TO – “FIRST TIME START-UP
INNOVATOR MEGAJECT”
ABNORMAL CONDITIONS OBSERVED AND CORRECTED
Abnormal Condition
a
a
a
a when
corrected
OPERATORS NAME _____________________________DATE: _____________
SIGN OFF WHEN PRE-START CHECKS ARE COMPLETED: ____________________________