Innovator Megaject
SP4 SOLVENT PUMP ASSEMBLY
SP4 Solvent Pump Assembly – The SP4 performs a 200cc solvent purge
followed by an air purge to thoroughly clean and purge the injection head and
mixer. It is contained in a 3 gallon Stainless Steel flush tank. During the flush
cycle only the SP4 solvent pump will be pressurized to force out the solvent
contained inside and then purges with air for the reminder of the flush cycle.
The SP4 is activated by pressing the Flush button on the control panel and will
operate for 30 to 60 seconds. The duration of the flush / purge cycle can be
adjusted as previously noted in the Section 2 – Control Box configuration.
Connecting the SP4 – Connect the yellow outlet tube from the outlet side of the
solvent pump through the outlet fitting to the flush neck on the flush valve of the
injection gun.
Connect the red 4mm tube to the fitting on the inlet side of the quick exhaust.
Connect the 1/4" pump inlet air tube to the other side of the inlet quick exhaust.
Yellow outlet tube connects
from injection gun flush
valve to the outlet of the
SP4 solvent pump.
Red 4mm flush signal line
1/4” Pump inlet air tube
Flush Tank
Inlet air tube loops up and
down through the inlet fitting
and connects to the inlet of
the solvent pump