beautypg.com

Liquid Controls HML4-F1 - LCMag User Manual

Page 12

background image


HML4-F1

12

DIGITAL INPUT

The functions refer to the inputs could be substantially divided in three groups:

1.

only assignable functions to the input 1

2.

functions that act directly on the inputs independently from the select input

3.

only assignable functions to the input 2 and only to the input 3 which they
interact between them


Remember that the activation of any functions of batch automatically disable the
operation of other. The list of such functions is suitable in the table of the batch
function configuration section.








































5/33 VDC (ON)
0/1.5 VDC (OFF)

25 (+)

26 (-)

10 K

Input electric wiring

ATTENTION: where not specified the time T
must be to Tmin

Speed rate

Tmin

20 Hz
50 Hz

80 Hz

150 Hz

110 ms

45 ms

30 ms
15 ms

60 Hz

40 ms