lectroCount lCR-II overview

GeneRal InfoRMaTIon

The Liquid Controls LectroCount LCR-II is a

microprocessor-based electronic meter register that

can be used for Weights & Measures approved custody

transfer actions in mobile or fixed installations. The

LCR-II can control a meter system as a stand-alone

unit, or it can be used as a slave to a host contoller such

as a process controller or an in-cab data management

system.

InPUTs

In order to calculate flow measurements from a positive

displacement meter, the LCR-II receives a pulse input

from an internally mounted quadrature pulser that is

mechanically connected to the flow meter (retrofit kits

are available for installation onto Neptune, Brooks,

and Smith positive displacement meters). This pulse

output can also come from a Liquid Controls external

POD pulser or another pulse generator. In addition to

the pulse input, the LCR-II is equipped with an input for

a temperature probe, so the register can compensate

volume measurements according to the temperature of

the product.

oUTPUTs

The LCR-II is equipped with a scaled pulse output, two

auxiliary outputs, and two solenoids outputs. These

outputs allow the LCR-II to communicate with meter

system accessories such as solenoid-controlled valves,

optical air and vapor eliminators, remote displays,

printers, and third-party devices.

CoMMUnICaTIons

The LCR-II is capable of interfacing in RS-232 and RS-

485 communication protocols.

hoUsInG

The LectroCount LCR-II housing and base are aluminum

die cast and powder coated. The hinge door design

provides easy access to the internal connections and

a Weights and Measures sealable fastener opposite

the hinges. There are seven machined ports, five ½”

NPT ports and two ¾” NPT ports, on the back of the

LectroCount LCR-II to provide secure cable connections

for all external devices.

dIsPlay

The 1” display is a six character, backlit LCD display.

navIGaTIon Keys

The LCR-II has two domed navigation keys to perform

basic configuration and functions. The keys collapse

and recover to give a tactile, positive confirmation of

keystrokes.

seleCToR sWITCh

The selector switch controls basic stop, run, print, and

shift print delivery functions. To perform calibration

functions, the cover plate must be removed and the

selector switch turned to the six o’clock position.

fUnCTIonalITy and oPeRaTIon

The principle functions of the LectroCount registers

include:

• Calibration (single and multipoint)

• Weights & Measures custody transfer

(product delivery and ticket generation)

• Metrological data collection

• Presetting by volume

• Multiple production selection

• Security settings

• Air and vapor elimination (with proper accessories)

• Valve control (with proper accessories)

• Electronic temperature volume compensation

(ETVC) (with proper accessories)

lCR-II oveRvIeW