beautypg.com

Maintenance requirements, Disclaimer, Warning – Liquid Controls M-MA Meters User Manual

Page 12

background image

▪ prevent pIpe straIn or stress

Prevent pipe strain or stress from occurring when making meter or

accessory repairs. Pipe strain and stress occurs when the pipes

are not supported or are not aligned correctly to the meter. The

weight of the pipes must always be supported independent of the

meter. This means that the meter and accessories can be easily

removed without affecting the pipes or the pipe alignment. Never

leave any of the pipes hanging.

▪ seasonal Meter storaGe

If the meter is used for seasonal work, the meter should

be removed from the system and thoroughly flushed with a

compatible liquid at the end of each season. To flush the meter,

remove the drain plug on the front and rear covers. Then flush the

product from the front and rear covers. If flushing with water, extra

care should be taken to drain the meter completely and dry all

internal parts. Refill the meter Immediately with a compatible liquid

(or oil misting). Refilling is essential to preventing corrosion and

ice damage that can result from any moisture that was overlooked

after flushing and drying.

▪ do not Mar or scratch

Do not mar or scratch any of the precision machined surfaces by

prying or sanding parts.

▪ torque all fasteners

Torque all fasteners such as screws and bolts in accordance with

specifications listed in the Torque Chart on page 21.

▪ stone the MachIned surfaces

Stone the machined surfaces when reassembling the meter to

assure that the machined surfaces are free of burrs and mars.

▪ repaIr pulled threads

Repair pulled threads with threaded insert fasteners. These can

be used in many instances. Contact your full-service distributor for

advice if this occurs.

▪ coat threads WIth antI-seIze

Coat threads with anti-seize when removing and replacing bolts

and castings in the meter.

▪ reMovInG flanGe Gaskets

Removing flange gaskets When removing the flange assembly,

always carefully scrape off the flange gaskets. Make sure that the

flange surface has been scraped clean. Discard the old flange

gasket and install a new flange gasket. Never reuse old flange

gaskets.

▪ exaMIne all fasteners

Examine all fasteners to make sure they are not bent, rusted, or

have pulled threads. The threads should all appear evenly placed.

If the bolts are bent, check the housing and cover for flatness. Use

a straight edge to determine flatness.

▪ look for Gaps

Look for gaps when disassembling a meter. Use a feeler gauge

to check for gaps between the bearing plate and housing. If you

do find gaps, check the bearing plates for flatness with a straight

edge. Gaps can be caused by shock problems. If shock problems

exist, they must be resolved. Contact your full-service distributor

for assistance if this occurs.

▪ check the o-rInGs

Check the O-rings for damage. Cracked, rough, or worn O-rings

should be replaced. However, a more serious problem of shock

may be indicated if the O-rings look nibbled. Shock problems must

be verified and resolved. Contact your full-service distributor for

assistance if this occurs.

▪ check the bearInG plates

Check the bearing plates for flatness. Use a straight edge.

Warped bearing plates can be caused by shock problems. If shock

problems exist, they must be resolved. Contact your full-service

distributor for assistance if this occurs.

▪ check WIth reGulatory aGency

Check with regulatory agency that governs Weights & Measures

in your area. Removing the dust cover seal wire or other

maintenance procedures may require Weights & Measures

recalibration.

MaIntenance requIreMents

Before disassembly of any meter or accessory component:

• all internal pressures must be relieved and all liquid drained from the system in

accordance with all applicable procedures.

• pressure must be 0 (zero) psi.
• close all liquid and vapor lines between the meter and liquid source.

For Safety Rules, refer to local authorities and relevant NFPA Codes.

failure to follow this warning could result in property damage, personal injury, or death from

fire and/or explosion, or other hazards that may be associated with this type of equipment.

!

WarnInG

Liquid Controls disclaims all liability for damage to

meter or accessories because of corrosion, salting

out of product, or separation of chemicals whether

occurring during periods of use or storage.

DISCLAIMER

12