beautypg.com

Three phase schematic – Controlled Products Systems Group SL58510011G3 User Manual

Page 32

background image

32

A1

A1

Y/BK

ON/OFF
SWITCH

ON

OF F

40-32357F

A

XFMR

(TB2)

J2 PLU G
ON PCB

POWER IN
SEE NOTE 1

AB

CD

TO MOTOR

SEE NOTE 5
MOTOR
OVERLOAD

AUXILIARY RELAY
EXTERNAL OVERLOAD

LINE

BLACK (SL595 ORANGE)

SEE NOTE 3

LOAD
24VAC/60VA

BLUE

YELLOW

FUSE 3.2A

FREE EXIT LOOP

RADIO

TERMINAL

BLOCK

FACTORY

INSTALLED RADIO

(100db)
SAFETY
ALARM

-

+

1

2

3

4

5

6

7

8

9

10

12

13

14

15

16

17 18 19

20

11

(TB1)

PURPLE

PUR/

W

HT

RESET

STOP

GREE

N

YEL/BLK

BRO

WN

ORA

N

GE

GREE

N

GRAY

BLACK

BLACK

BLUE

W

HITE

RED

OR/BLK

BLUE

OR

TB1-7

GRN

TB1-4

Y/BK

TB1-3

OPEN

CLOSE

STOP

TB1-5

J1-3

Y/BK

RESET

RADIO

SHADOW

VDC COM

CLOSE

ST

OP

SOFT OPEN

HARD OPEN

INTERRUPT

OPEN CLOSE

EDGE/PHOTO

EYE

MASTER
SECOND

MAGLOCK

EXIT LOOP

FIELD CONNECTIONS

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

J1

J4

1 2

J2

(GL CONTROL BOARD)

Y/BK

TO J2-1

CONTACTOR

TB2-CD

PURPLE

Y (SL595 WHT)

GY (SL595 GN)

PU (SL595 RD)

A1
13

5
3
1

A2
14

6
4
2

B

A1
13

5
3
1

A2
14

6
4
2

WHITE

ORANGE

TO J2-2

WHITE

BLACK

BK

BK

BK

BLUE

YELLO

W

BLUE

YELLO

W

RPM

BOARD

ORANGE

PURPLE

GREEN

GROUND

CONTACTOR A

CONTACTOR B

ORANGE

PURPLE

BLACK

RED

WHITE

11

10

9

8

7

6

5

2

1

4

3

TB1-15

TB1-3

TB1-6

ALARM

4

R1

R2

R3

R4

BLUE

BLACK

Y/BK

BROWN

GREEN

OR

PU

1

2

L/S “A”NC

C

L/S “B”NC

C

YEL/BLK

Y/BK

3

GY

1

3

2

BL-BK

BL-BK

230V
BRAKE
SOLENOID

230V CONNECTION

LOOP WIRING

R4

TB1-5

TB2-AB

TB2-CD

FREE EXIT

LOOP

HARNESS

(10 PIN)

TB1-8

TB1-3

TB2-AB

TB2-CD

INTERRUPT

LOOP

HARNESS

(10 PIN)

4

6

7

8

9

10

BK

BK

PU

7

8

9

4

5

6

460V CONNECTION

230V
BRAKE
SOLENOID

1

3

2

BL-BK

BL-BK

BK

BK

PU

7

8

9

4

5

6

Y

Y

575V CONNECTION

575V
BRAKE
SOLENOID

BL-BK

BL-BK

1

3

2

GY

BK

BK

PU

Y

GY

R1

R2

YELLO

W

BK
BK

BK

L1

L2

L3

BK

SEE NOTE 5
EXTERNAL
OVERLOAD

NOTES:
1. VOLTAGE: 208/230/460/575 VOLT 3 PHASE.
2. HORSEPOWER: 1/2, 1 & 2 HP.
3. TRANSFORMER PRIMARY VOLTAGE IS THE SAME AS THE OPERATOR LINE VOLTAGE. SECONDARY 24V/60VA.

FOR REFERENCE PRIMARY WIRE COLORS: 120V BLACK, 208V RED, 230V ORANGE, 460V PURPLE, 575V GREY

4. TERMINAL BLOCK IN LIMIT SWITCH ENCLOSURE (SL595 ONLY).
5. THREE PHASE UNITS ARE EQUIPPED WITH AN INTERNAL PILOT DUTY THERMAL OVERLOAD

DEVICE OR AN EXTERNAL LINE MONITORING SYSTEM.

24 VAC

RADIO

SIGNAL

TB2-20

TB2-19

TB2-18

TB2-17

To protect against fire and electrocution:
• DISCONNECT power BEFORE installing or servicing operator.

W

W A

A R

R N

N I

I N

N G

G

YELLO

W

24 VAC ACCESSORY

POWER

INTERRUPT

LOOP

Y/BK

RD

BK

4

6

7

8

9

10

G

YELLOW

Y/BK

T H R E E P H A S E S C H E M A T I C