beautypg.com

Three phase wiring diagram – Controlled Products Systems Group SL58510011G3 User Manual

Page 31

background image

31

6

2

1

3

7

9

1

2

5

A

B

3

4

B

4

A

A

B

2

1

6

OVERLOAD

3

5

230V
BRAKE
SOLENOID

(BK)

(GN)

(BK)

(GY) (SL595 GN)

(PU) (SL595 RD)

(BK)

(YE) (SL595 WH)

(GY) (SL595 GN)

(PU) (SL595 RD)

(YE) (SL595 WH)

(GY) (SL595 GN)

(PU) (SL595 RD)

(YE) (SL595 WH)

(WH)

PRIMAR

BLACK (SL595 ORANGE)

Y

L1

L2

230V
BRAKE
SOLENOID

(BK)

(BK)

(SEE NOTE 3)

(BK)

(BK)

(BK)

8

4

5

6

2

1

3

7

9

(BK)

(BK)

8

4

5

6

230V CONNECTION

460V CONNECTION

575V
BRAKE
SOLENOID

2

1

3

(BK)

(BK)

575V CONNECTION

(SEE NOTE 2)

24V Sec.

FUSE
3.2A

(TB 2)

AB

CD

24VAC

RADIO

SIGNAL

RAD

IO BLOCK

R1

R2

R3

R4

(BL)

(BL)

(YE)

4

6

7

8

9

10

4

6

7

8

9

10

TB1

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

-

+

J4 PLUG

1
2

J1-1

J1-2

J1-3

J1-4

J1-5

J1-6

J1-7

J1-8

J1-9

J1-10

J1-11

J1-12

J1-13

J1-14

J1-15

J1-16

J1 PLUG

FREE EXIT

LOOP HARNESS

10 PIN - 1,2,3,5

CAPPED

INTERRUPT

(SAFETY)

LOOP HARNESS

10 PIN - 1,2,3,5

CAPPED

J2 PLUG

J2-3
J2-4
J2-5
J2-6
J2-7
J2-1

J2-8

J2-9

J2-10
J2-11

J2-2

L/S B

NC

COM

NC COM

L/S A

B

A

A1

A2

A1

A2

(YE)

(BK)

(Y/BK)

(RD)

(SEE NOTE 1)

= TERMINAL BLOCK IN LIMIT SWITCH ENCLOSURE (SL595 ONLY).

(WH)

(RD)

(BK)

3

2

1

(GN)

(WH )

(RD)

(BK)

(BRN)

(GY)

(GN)

(WH )

(RD)

(BK)

(BRN)

(GY)

(BL)

(YE)

(GN)

(PU)

(OR)

(PU)

(PU/WH)

(Y/BK)

(GN)

(Y/BK)

(BRN)

(OR)

(GN)

(GY)

(OR/BK)

(BK)

(BK)

(BL)

(RD)

(WH)

(RD)

(WH)

(PU)

(P/W)

(Y/BK)

(GN)

(Y/BK)

(Y/BK)

(WH)

(BRN)

(OR)

(GN)

(GY)

(OR/BK)

(WH)

(RD)

(BK)

(BK)
(BL)

(YE)

(GY)

(BRN)

(GY)

(BRN)

(Y/BK)

(OR)

(Y/BK)

(GN)

(Y/BK)

(YE)

(YE)

(BL)

(BL)

(BRN)

(PU)

(OR)

(BL)

(BL)

(BK)

(BK)

(YE)

(YE)

(YE)

(RD)

(RD)

L3

(BK)

(BK)

FACTORY

INSTALLED RAD

IO

40-32351E

3 PHASE

POWER IN

ON/OFF
SWITCH

GROUND

SAFETY ALARM

(100 db)

NOTES:
1) Transformer primary voltage is the same as the operator line voltage. Secondary 24V 60VA.
2) Wire color: 208V red, 230V orange, 460V purple, 575V gray.
3) Three phase units are equipped with an internal pilot duty thermal overload
device or an external line monitoring device.

DUAL

GATE

GL CONTROL BOARD

24VAC-IN

24VAC-COMMON

SOFT OPEN

NC

"B" LIMIT

CONTACTOR B

"A" LIMIT

CONTACTOR A

RPM - IN

RPM - SUPPLY

RPM GND

RADIO COMMAND

SHADOW

+24VDC

CLOSE

STOP

SOFT OPEN

HARD OPEN

INT. LOOP

OBS. OPEN

OBS. CLOSE

24 VAC-COMMON

DC-GND

LOCK 1

LOCK 1

ALARM 1

ALARM 1

RADIO

SHADOW

VDC COM

CLOSE

STOP/COM

SOFT OPEN

HARD OPEN

INTERRUPT (SAFETY)

OPEN

CLOSE

MASTER / SECOND

MAGLOCK

24 VAC

INTERRUPT LOOP (SAFETY)

EXIT LOOP

FIELD CONNECTIONS

EDGE/PHOTOEYE (SAFETY)

STOP

RESET

OPEN

CLOSE

RPM

SENSOR

SEE NOTE 3

T H R E E P H A S E W I R I N G D I A G R A M