Specifications – Controlled Products Systems Group 6500-083 User Manual
Page 2
Class of Operation
Model 6500 - UL325 Class I, II, III, IV
Type of Gate
Vehicular Swing Gates Only
Horsepower
1/2 or 1 HP
Voltage / Phase
115 VAC Single-Phase, 230 VAC Single-Phase, 460 VAC Single-Phase
Current
½ HP –
5.4 Amps @ 120V; 2.7 Amps @ 230V; 1.35 Amps @ 460V
1 HP –
9.7 Amps @ 120V; 4.9 Amps @ 230V; 2.5 Amps @ 460V
Max Gate Weight
1/2 HP - 600 Lbs.; 1 HP - 800 Lbs.
Max Gate Length
1/2 HP - 18 Ft.; 1 HP - 22 Ft.
Cycles Per Hour
60 Per Hour
Speed
90° in approximately 12-14 seconds
Entrapment Protection
Primary -
Inherent entrapment sensing system (Type A)
Secondary -
Provision for connection of a non-contact sensor (Type B1)
SPECIFICATIONS
Use this manual with the following models only:
6500-080, 6500-081, 6500-082*, 6500-083*, 6500-084, 6500-085, 6500-086*, 6500-087*, 6500-088, 6500-089*, 6500-090,
6500-091*, 6500-092, 6500-093*, 6500-094, 6500-095*, 6500-096, 6500-097*, 6500-098, 6500-099*.
*Optional Convenience Open System
DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any
persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is
copyrighted, all rights reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written
consent from DoorKing, Inc.
28
3
/
8
”
18
3
/
8
”
23
1
/
4
”
31
5
/
8
”
1
6500-065-E-2-08