5 loop detector wiring, Reverse, Reverse automatic exit shadow – Controlled Products Systems Group 6500-083 User Manual
Page 18
17
Automatic exit loop
lead in wires are
twisted approx. 6
twists per foot.
Reverse loop lead in
wires are twisted
approx. 6 twists per
foot and are wired in
series.
Shadow loop lead in
wires are twisted
approx. 6 twists per
foot.
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Reverse
Reverse
Automatic Exit
Shadow
2.5 Loop Detector Wiring
•
If other detectors are used, use a separate power
supply to power these detectors.
•
Loop layout shown is for a typical swing gate
application with two-way traffic, or one-way exit
only
traffic.
•
Refer to the Loop Information Manual (available
from
www.dkaccess.com
) for more information
on loops and loop detectors.
Loops and loop detectors MUST be installed with this gate
operator to help prevent the gate from accidentally closing
on vehicular traffic.
•
Loop detector wiring is shown for DoorKing plug-in loop
detectors only. If other loop detectors are used, refer to
the installation instructions supplied with those detectors
for wiring instructions.