6500-065-E-2-08

2.4 Control Wiring

Radio Receiver

power only.

Power is limited to 250 ma.

Open direction non-contact sensor.
Stops the gate in the open cycle only.
Gate resumes normal operation when
the obstruction is cleared.

Close direction non-contact sensor.
Reverses gate during the closing
cycle only. Holds gate in the full open
position until obstruction is cleared.

Diagram at right is for illustration purposes. The actual

placement of the secondary protection devices is

dependent on the specific installation requirements.

Secondary entrapment protection devices must be

installed with this gate operator. This protection may
be provided by non-contact or contact sensors, or a
combination of both.

Secondary device wiring shows inputs to the circuit

board only. Photo-cells must be supplied with power.

Refer to the safety instructions in the front of this manual

for more information.

Controls must be installed a minimum of 10-feet from

the gate or installed in such a way that the person
using the control cannot come in contact with the gate
or gate operator.

All inputs to the 4405 circuit board are Normally Open (N.O.).

Magnetic Lock

Power (24-Volt DC) and logic
output. Power is shut off .5 sec.
prior to gate starting and
remains off while gate is opening
and in the open position.

Com

Com

Relay

24 Volt

24 Volt

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

1

2
3
4

5

6

Key Switch

Fire Box

Stand-Alone

Keypad

Stand-Alone

Card Reader

Telephone Entry

Remote Terminal

B

B

A

A

A

Terminal 6 reverse input
functions only when gate is in
the closing cycle when SW 1,
switch 5 is OFF.

Note: SW 1,
switch 3
must be ON.

Note: All stand-alone
and telephone entry
devices must use a
separate power source.

11

ON

2

3

4

5

6

7

8

SW 1

1

ON

2

3

4

5

6

7

8

SW 1