4 control wiring – Controlled Products Systems Group 6500-083 User Manual
Page 17
16
6500-065-E-2-08
2.4 Control Wiring
Radio Receiver
power only.
Power is limited to 250 ma.
Open direction non-contact sensor.
Stops the gate in the open cycle only.
Gate resumes normal operation when
the obstruction is cleared.
Close direction non-contact sensor.
Reverses gate during the closing
cycle only. Holds gate in the full open
position until obstruction is cleared.
•
Diagram at right is for illustration purposes. The actual
placement of the secondary protection devices is
dependent on the specific installation requirements.
•
Secondary entrapment protection devices must be
installed with this gate operator. This protection may
be provided by non-contact or contact sensors, or a
combination of both.
•
Secondary device wiring shows inputs to the circuit
board only. Photo-cells must be supplied with power.
•
Refer to the safety instructions in the front of this manual
for more information.
•
Controls must be installed a minimum of 10-feet from
the gate or installed in such a way that the person
using the control cannot come in contact with the gate
or gate operator.
•
All inputs to the 4405 circuit board are Normally Open (N.O.).
Magnetic Lock
Power (24-Volt DC) and logic
output. Power is shut off .5 sec.
prior to gate starting and
remains off while gate is opening
and in the open position.
Com
Com
Relay
24 Volt
24 Volt
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
Key Switch
Fire Box
Stand-Alone
Keypad
Stand-Alone
Card Reader
Telephone Entry
Remote Terminal
B
B
A
A
A
Terminal 6 reverse input
functions only when gate is in
the closing cycle when SW 1,
switch 5 is OFF.
Note: SW 1,
switch 3
must be ON.
Note: All stand-alone
and telephone entry
devices must use a
separate power source.