November, 2003

400 Operator And
455 D Control Panel Installation Manual

M

ANUAL

R

ELEASE

M

ECHANISM

For installation of the locking cap cover see page 20. To

access the keyhole, slide the key-hole cover in the

direction of the arrow (see Figure 3). Insert the key and

turn it counterclockwise one full turn to disengage the

operator’s hydraulic system. You can now move the gate

leaf slowly by hand to open or close the gate.

Operating the gate leaf by hand is necessary during

installation and is useful during power failures.

You re-engage the hydraulic system by turning the key

clockwise one full turn. Remove the key and slide the

cover closed.

I

NSTALLING

THE

O

PERATOR

Installing the 400 operator consists of the following

steps:

1. Attach the rear mounting bracket

2. Attach the mounting hardware

3. Attach the front mounting bracket

4. Attach the operator to the gate

5. Adjust

the

operator

pressure

A

TTACH

THE

R

EAR

M

OUNTING

B

RACKET

Attach the rear mounting bracket according to the

dimensions in Figure 4.

WARNING!

You must achieve the A and B

dimensions, as specified in Figure 4.

Modification of the rear bracket may be

necessary to achieve these dimensions (I.e.,

cutting or extending the bracket provided)

If you have a steel gate post, weld the rear bracket

directly to it. If the gate post is made of any other

material, attach the optional mounting plate, with lag

bolts or anchors, and weld the bracket to it.

For an outward swing gate refer to Figure 5.

A

TTACH

THE

M

OUNTING

H

ARDWARE

Figure 2. Positive Stops

Figure 3. After sliding the cover open on the

Model 400, insert and turn the key

counterclockwise one full turn to release the

hydraulic system