beautypg.com

455 d c, Ont r ol, Ane l – Controlled Products Systems Group 1042011577 User Manual

Page 24: Ns ta ll a t io n, Ns tru c ti o n s

background image

Page 24

November, 2003

400 Operator And

455 D Control Panel Installation Manual

T

HE

455

D

C

ONT

R

OL

P

ANE

L

I

NS

TA

LL

A

T

IO

N

I

NS

TRU

C

TI

O

N

S

A (Automatic) Logic (455 D)

Gate Status

Open A

Open B

Stop

Opening

Reversing

Device(s)

Closing

Reversing

Device(s)

Warning Light

Closed

Opens both leaves

and closes them
after pause time

Opens single leaf

connected to Motor

1 and closes it after

pause time

No effect

No effect

No effect

Off

Opening

No effect

No effect

Stops

Stops; gate closes

when reversing de-
vice no longer trig-

gered

No effect

On

Opened

Interrupts the

pause time

Interrupts the

pause time

Stops

No effect

Gate remains open

until reversing devices

no longer triggered

On

Closing

Opens both leaves

Opens leaf

Stops

No effect

Depends on DIP

switch 4

Flashes

Stopped

Closes the leaves

Closes the leaf

No effect

(opening is

inhibited)

No effect

No effect

(opening is inhibited)

On

Gate Status

Open A

Open B

Stop

Opening

Reversing

Device(s)

Closing

Reversing

Device(s)

Warning Light

Closed

Opens both leaves

and closes them after

pause time

Opens single leaf

connected to Motor

1 and closes it after

pause time

No effect

No effect

No effect

Off

Opening

Closes both leaves

Closes leaf

Stops

Stops; gate closes

when reversing de-
vice no longer trig-

gered

No effect

On

Opened

Closes both leaves

Closes leaf

Stops

No effect

Gate remains open

until reversing devices

no longer triggered

On

Closing

Opens both leave

Opens leaf

Stops

No effect

Depends on DIP

switch 4

Flashes

Stopped

Closes the leaves

Closes the leaf

No effect

(opening is

inhibited)

No effect

No effect (opening is

inhibited)

On

S (Security) Logic (455 D)

Gate Status

Open A

Open B

Stop

Opening

Reversing

Device(s)

Closing

Reversing

Device(s)

Warning

Light

Closed

Opens 1 or both

leaves

No effect

No effect

No effect

No effect

Off

Opening

No effect

No effect

Stops

No effect

Stops

On

Opened

No effect

Closes 1 or both

leaves

No effect

No effect

No effect

On

Closing

No effect

No effect

Stops

Stops

No effect

Flashes

Stopped

Opens 1 or both

leaves

Closes 1 or both

leaves

No effect

No effect

No effect

On

B (Manned, Pulsed) Logic (455 D)

This manual is related to the following products: