beautypg.com

455 d c, Ontr o l, An el – Controlled Products Systems Group 1042011577 User Manual

Page 25: Nst a llat ion, Nst r uct ions, E (semi-automatic) logic (455 d), Ep (semi-automatic, step by step) logic (455 d), C (manned and constant) logic (455 d)

background image

Page 25

November, 2003

400 Operator And
455 D Control Panel Installation Manual

T

HE

4

55 D

C

ONTR

O

L

P

AN
EL

I

NST

A

LLAT

ION

I

NST

R

UCT

IONS

E (Semi-automatic) Logic (455 D)

Gate Status

Open A

Open B

Stop

Opening

Reversing

Device(s)

Closing

Reversing

Device(s)

Warning

Light

Closed

Opens both leaves

Opens single leaf

connected to

Motor 1

No effect

No effect

No effect

Off

Opening

Stops

Stops

Stops

Stops; gate closes

when reversing

device no longer

triggered

No effect

On

Opened

Closes both leaves

Closes leaf

Stops

No effect

No effect

(opening is inhib-

ited)

On

Closing

Closes both leaves

Closes leaf

Stops

No effect

(opening is inhibited)

Depends on DIP

switch 4

Flashes

Stopped

Closes the leaves

Closes the leaf

No effect

(opening is

inhibited)

No effect

No effect

opening is inhib-

ited)

On

Gate Status

Open A

Open B

Stop

Opening

Reversing

Device(s)

Closing

Reversing

Device(s)

Warning

Light

Closed

Opens both leaves

Opens single leaf

connected to

Motor 1

No effect

(opening is in-

hibited)

No effect

(opening is inhibited)

No effect (opening

is inhibited)

Off

Opening

Stops

Stops

Stops

Stops; gate closes

when reversing

device no longer trig-

gered

No effect

On

Opened

Closes both leaves

Closes leaf

Stops

No effect

No effect (opening

is inhibited)

On

Closing

Stops

Stops

Stops

No effect

(opening is inhibited)

Depends on DIP

switch 4

Flashes

Stopped

Gate leaves reverse

direction

Gate leaf reverses

direction

No effect

(opening is in-

hibited)

No effect

(opening is inhibited)

No effect

(opening is inhib-

ited)

On

EP (Semi-automatic, Step by Step) Logic (455 D)

Gate Status

Open A

Open B

Stop

Opening

Reversing

Device(s)

Closing

Reversing

Devices(s)

Warning

Light

Closed

Opens 1 or

both leaves

No effect

No effect

No effect

No effect

Off

Opening

No effect

No effect

Stops

No effect

Stops

On

Opened

No effect

Closes 1 or

both leaves

No effect

No effect

No effect

On

Closing

No effect

No effect

Stops

Stops

No effect

Flashes

Stopped

Opens 1 or

both leaves

Closes 1 or

both leaves

No effect

No effect

No effect

On

C (Manned and Constant) Logic (455 D)