E (semi-automatic): This mode requires a
command to open and a command to close.

A second command during opening stops the

gate. A second command during closing

reopens the gate.

EP (semi-automatic, step by step): This mode
requires a command to open and a command

to close. A second command during opening

or closing causes the gate to stop. A third

command then reverses the previous motion

of the gate.

B (manned, pulsed): This mode is designed
for guard station use and requires a three-

button switch (pulsed) to open, close, and

stop the gate.

C (manned and constant): This mode requires
constant pressure switches. One to open and

one to close. No pressure on a switch stops

the gate.

The three programming push buttons allow the

programming of the torque (or pressure), the pause

time between opening and closing, and the leaf delay

on closing.

WARNING! Turn the main power off before you

make any electrical connections.

For all FAAC hydraulic operators using the 455 D

control panel, the force must be set at its maximum

setting of 50 in order to supply the correct voltage to

the operator.

P

AUSE

T

IME

: The pause time between opening and

closing can be adjusted from 0 seconds to 4 minutes.

Time is adjusted in one-second increments from 0—

59 seconds. When 60 seconds is reached, time is

adjusted in 10 second increments up to 4 minutes.

i.e. if display shows 2.5, it means 2 minutes and 50

seconds.

L

EAF

D

ELAY

: You may choose to delay one leaf on

closing for overlapping gate leaves. Be sure the

operator on the leaf for delayed closing is connected

to Motor 1. On opening, the leaf connected to Motor 2

is delayed 2.5 sec.

N

OTE

: If an opening leaf delay is desired, it must

be enabled in the Advance Programming.

However, if enabled, you cannot

adjust this

opening delay of the operator connected to

Motor 2.

The closing leaf-delay time is adjustable from 0 to 4

minutes.

N

OTE

: If the opening/closing time is set at less

than the leaf delay time, the delayed leaf closes

at the end of the closing time.

Page 18

November, 2003

400 Operator And

455 D Control Panel Installation Manual

opening and closing, respectively, are triggered. Use

the LEDs and the next table to determine if the

accessory devices you have installed are operating

properly.

Electric Locks: An electric lock can be wired to the 455

D in terminals 18 and 21 (12Vac pulsed provided). If a

reversing stroke is needed to allow the electric lock to

release, this must be done in advanced programming.

See page 19 for the connections for a magnetic

locking device.

W

ARNING

L

IGHT

: Connect a warning light to

terminals 18 and 20 in the group labeled

W.LIGHT

in terminal block J1 and J5. The terminals provide

an output voltage of 24 VDC, maximum power 3

Watts. This output voltage will power most 24 VDC

warning lights.

N

OTE

: The behavior of the warning light varies

according to the logic you have set.

L

OGICS

A, S, E, EP,

AND

B: The warning light is on

steadily during opening and the pause phase. During

closing, the light flashes.

L

OGIC

C: The warning light is on steadily during

opening and flashes during closing.

S

ET

O

THER

O

PERATING

C

ONTROLS

WARNING! Turn the main power off before you

make any electrical connections.

You need to program the control panel for your gate's

operation. The 455 D Control Panel has on board

programming that controls a wide range of functions.

O

PERATING

L

OGICS

N

OTE

: The 455 D Control Panel provides inputs

for opening reversing devices and closing

reversing devices. FAAC strongly recommends

the use of reversing devices, such as photocells

or other non-contact sensors.

A (automatic): The gate opens on command
and automatically closes after a pause phase. A

second command while opening is ignored; a

second command during the pause phase

interrupts the pause time; a second command

during closing reopens the gate. A maintained

open command will hold the gate open.

S (security): The security mode is like A logic
except that a second command during opening

immediately closes the gate. A maintained

open command will not hold the gate open.

T

HE

455 D C

ON

T

R

OL

P

ANEL

I

NS

TA

LL

ATIO

N

I

N

STR

U

C

TI

O

N

S