beautypg.com

400 o, Perator, Nstallation – Controlled Products Systems Group 1042011577 User Manual

Page 6: Nstructions

background image

T

HE

400 O

PERATOR

G

ENERAL

C

HARACTERISTICS

The FAAC 400 Operator is an automatic gate operator

for a swinging gate leaf. It can accommodate a gate leaf

of up to 2000 lb (900 kg) and up to 20 ft (6 m) in

length.

The self-contained 400 Operator is an electro-hydraulic

unit consisting of an electric motor, a pump, a valve

assembly, and a hydraulic cylinder, all housed in an

anodized aluminum oil reservoir.

The 400 Operator can be used to swing the gate leaf

inward or outward. Most versions provide hydraulic

locking in at least one position, either opened or closed,

depending on how it was ordered.

The hydraulic lock is a service device rather than a

security device. Additional, external locks are

recommended under the following conditions:

You are installing the Model 400 SB

The length of the gate leaf is 12 ft or more

The installation requires tight security

The site is subject to vandalism

The site is subject to strong or very gusty wind

You are installing a solid face gate

For gates with two leaves, two operators are installed,

one on each leaf, and both are wired to one control

panel. In such two-operator gate installations, one leaf

can be programmed to open/ close slightly later than

the other leaf to accommodate overlapping gate

designs.

For its protection, the single-phase, bidirectional motor

shuts off automatically if its operating temperature

reaches 212 deg F (100 deg C). Also for the protection

and proper operation of the 400 Operator, each gate

leaf on which it is installed must have a fixed positive

stop in both the opened and closed positions.

The 400 Operator also includes a key-operated Manual

Release mechanism and two bypass valves that

pre­cisely control the force applied to the gate leaf

through the 400 Operator.

The Manual Release mechanism is a key-operated

device that disengages (or engages) the hydraulic

system of the 400 Operator. When the hydraulic system

is disengaged, you can open and close the gate leaf by

hand. Such manual operation of the gate is necessary

during installation and useful during power failures. The

two bypass valves are located beneath the locking cap.

You need to adjust the bypass valves to meet the safety

standards of FAAC International, Inc. The standards

state that the gate leaf should stop if it encounters a

force of more than 33 lb (15 kg).

Additional reversing devices (such as inductive loops

and photocells) should be installed to provide more

complete protection for people and property.

The electronic control panel is a microprocessor-based

controller that accepts a wide range of product

accessories and reversing devices, thus allowing for

flexible gate system design.

Page 6

November, 2003

400 Operator And

455 D Control Panel Installation Manual

P

REPARING

THE

G

ATE

Before installing the 400 Operator, you need to prepare

the gate itself for the operator. Be sure to do the

following things:

1. Make sure that the gate is plumb.

2. Make sure that the gate moves smoothly on its

hinges without excessive friction by swinging

it open and closed by hand. Lubricate all the

gates’ moving parts.

3. Provide positive stops for the gate leaves in

the fully open and fully closed positions (see

Figure 2).

I

NSTALLATION

I

NSTRUCTIONS

Installing the 400 Operator involves preparing the gate,

installing the operator(s), installing the control panel,

and fine-tuning the pressure adjustments on the

operator(s).

Note: The following installation instructions

assume you are fully capable of installing an

operator. This manual does not instruct you in

designing a gate, installing a gate, or basic

electrical wiring. The installation tasks discussed in

this manual are tasks particular to the 400

Operator.

This manual is related to the following products: