Jog setup – CNB IPM3063P User Manual
Page 35
◎ Setup the general functions of Pan/Tilt motions.
• MOTION LOCK [ON/OFF]
- If Motion Lock is set to ON, it is impossible to set
up and delete Preset, Swing, Pattern and Group.
It is possible only to run those functions. To set
up and delete those functions, enter into OSD
menu.
• PWR UP ACTION [ON/OFF]
- Refer to “Other Functions" section.
• FRZ IN PRESET [ON/OFF]
- At start point of preset movement, camera starts freezing the image of start point.
Camera keeps displaying the image of start point during preset movement and does
not display the images which camera gets during preset movement. As soon as
camera stops at preset end point, camera starts displaying live images which it gets at
preset end point. This function availability should be different by models.
◎ Setup the Jog speed and Direction.
• AUTO FLIP [ON/OFF]
- Refer to “Other Functions" section.
• JOG MAX SPEED [1
°/sec~360°/sec]
- Sets maximum jog speed. Jog speed is inversely
proportional to zoom magnification. As zoom
magnification goes up, pan/tilt speed goes down.
• JOG DIRECTION [INVERSE/NORMAL]
- If you set this to ‘Inverse’, the view in the screen
is moving same direction with jog tilting.
If ‘Normal’ is selected, the view in the screen is
moving reversely.
◎ If Park Enable is set to ON, camera runs assigned
function automatically if there is no PTZ command
during assigned "Wait Time".
• PARK ENABLE [ON/OFF]
• WAIT TIME [1minute~4hour]
- The time is displayed with "hh:mm:ss" format and
you can change this by 1 min unit.
• PARK ACTION
[HOME/PRESET/PATTERN/SWING/GROUP]
HOME
Camera moves to home position if there is no
PTZ command during assigned "Wait Time".
◎ Match the Alarm sensor input to one of Preset
positions. If an external sensor is activated, camera
will move to corresponding preset position when
this item is predefined.
• ALARMx TYPE
[NORMAL OPEN/NORMAL CLOSE]
- Sets sensor input type.
• ALARMx ACTION
[NOT USED/PRESET 1~128]
- Assign counteraction Preset position to each
Alarm input.
MOTION SETUP
PARKING ACTION SETUP
ALARM INPUT SETUP
PARKING ACTION SETUP
PARK ENABLE
WAIT TIME
PARK ACTION
BACK
EXIT(MENU OFF)
OFF
00 :10 : 00
HOME
☞
ALARM INPUT SETUP
ALARM 1 TYPE
ALARM 2 TYPE
ALARM 3 TYPE
BACK
EXIT(MENU OFF)
N. OPEN
ALARM 4 TYPE
ALARM 1 ACT
ALARM 2 ACT
ALARM 3 ACT
ALARM 4 ACT
N. OPEN
N. OPEN
N. OPEN
NOT USED
NOT USED
NOT USED
NOT USED
☞
JOG SETUP
JOG SETUP
AUTO FLIP
JOG MAX SPEED
JOG DIRECTION
BACK
EXIT(MENU OFF)
ON
120 /SEC
INVERSE
☞
MOTION SETUP
MOTION LOCK
PWR UP ACTION
FRZ IN PRESET
> BACK EXIT(MENU OFF) OFF ON OFF ☞ > > 69 68