Base station registration, N. refer to, Appendix d: multiple base station registration – Clear-Com HME DX210 User Manual
Page 29

Appendix D: Multiple Base Station Registration
For multiple base stations to operate in close proximity without interference, they must all be properly
registered before performing any other setups. After registering each base station, register each
COMMUNICATOR
®
that will be used with that base according instructions in
section 2.3.2, page 8.
NOTE: If using split-band operation, select the appropriate band prior to base station registration. If a
different frequency band needs to be selected to avoid interference, the primary base station must be
set to this frequency band before base station registration is started.
Register each base station and all Belt Packs and/or All-In-One Headsets as follows:
●
On one of the base stations, ensure that the primary/secondary switch is set to primary. On the
others, ensure that it is set to secondary.
NOTE: In split band operation, there can be one primary and up to three secondary base stations in
either band.
●
Turn the primary base station power on. Register any Communicators to be used with the primary base
station, as instructed in
. Turn each Communicator off after registering it.
●
Power on one secondary base station. The STATUS display will show a double bar, indicating the
secondary base station is ready to be registered.
Double bar
Small “o”
Base station ready to be initialized Small "o" indicates primary base
station is open for registration
●
REG (register) b
STATUS display will show a small “o.”
Press the
utton on the primary base station. The
●
To assign a number to a secondary base station and register it, press the REG button on the
secondary base station. Pressing the button repeatedly causes it to cycle through the numbers 1, 2,
and 3. When the desired number appears, stop pressing and wait. While the secondary base station
is registered using the displayed number, the STATUS display will continue showing the secondary
number selected. When registration of the secondary base station is fin
one bar, to indicate the secondary has been registered to the primary.
ished, the display will show
●
section 2.3.2, page 8
Secondary 2 searching for primary
Secondary is initialized to primary
One bar
Secondary base number
●
Press the REG button on the primary. The STATUS display will go blank.
Register Communicators to the secondary base stations as instructed in
. After
registration, turn off the secondary base station and all Communicators.
23
Clear-Com HME DX210 System Guide