Register communicator®s, 2 register communicator – Clear-Com HME DX210 User Manual
Page 14

2.3.2 Register COMMUNICATOR
®
s
The Communicator must be within 6 feet (1.83 meters) of the base station to enable registration.
1. Be sure each Communicator you are going to register is turned off and the base station power
is on before you begin. Communicators that are already registered can be on or off.
2. Put the headset on your head.
3. Press the REG button on the front panel of the base station. The STATUS display will show a small
“o” for open.
STATUS display
“o”
REG button
NOTE: If you wait too long before going on to the next step, the base station will go out of the
registration mode and you will have to press the REG button again.
4. Press and hold the ISO button on the Communicator while you press and release the PWR (power)
button to turn the unit on, then release the ISO button. This will cause the Communicator to enter the
registration mode.
On Belt Packs, the two power lights at the corners near the IC1 and IC2 buttons will begin blinking
red, then will blink green two or three times and go off. Wait! There may be a short delay.
On All-In-One Headsets, the power/mode lights at the end of the microphone boom and on the
side of the unit near the IC1 button will blink. Wait! There may be a short delay.
If registration is successfully completed:
●
A voice message in the headset will say “Power on, Belt Pack #, Version #, Begin registration,
Registration complete, …”
●
After a delay of about 15 seconds, the STATUS display will show the ID number assigned to this
Communicator for about 10 seconds.
NOTE: ID numbers are assigned sequentially as 0 thru 9, A, b, C, d and E.
●
The power light on the Communicator will remain on steady green.
Repeat Steps 2 to 4 above for each Communicator to be registered.
If registration failed:
●
A voice message in the headset will say “Power on, Belt Pack #, Version #, Begin registration, …”
Both lights on the Belt Pack will be blinking red, and there may be a delay of up to 90 seconds before
you hear “Registration failed.”
●
Press the RESET button at the lower-left corner of the base station with a pen or similar pointed
object. When the STATUS display becomes blank, press the REG button and register the
Communicator again. If registration fails again, call your dealer for assistance.
8