Pair analog, Pair analog -13, Views from front of connectors – Clear-Com LMC-64 User Manual
Page 99
Clear-Com
Eclipse Median Instruction Manual
7 - 1 3
4-Pair Analog
Four-pair analog wiring is done with shielded CAT5 RJ-45 cable.
• Pair 1 transmits analog audio from the matrix to the panel.
• Pair 2 transmits digital data from the panel back to the matrix.
• Pair 3 transmits audio from the panel to the matrix.
• Pair 4 transmits digital data from the matrix back to the panel
.
Figure 7-5: Wiring from the Matrix to an Analog Panel Using RJ-45
RJ-45 CONNECTOR
AT MATRIX PORT
RJ-45 CONNECTOR ON
PANEL OR INTERFACE
Matrix Frame RJ-45 Pin Numbers
Shielded category-5 cables wired pin-to-pin
Panel RJ-45 Pin Numbers
Pair 2
Pair 1
Pair 3
Pair 4
RS-422 Input +
(into Matrix)
RS-422 Input –
(into Matrix)
Audio Input +
(into Matrix)
Audio Output +
(from Matrix)
Audio Output –
(from Matrix)
Audio Input –
(into Matrix)
RS-422 Output +
(from Matrix)
RS-422 Output –
(from Matrix)
1
2
3
5
6
7
1
2
6
7
8
4
3
4
5
8
RS-422 Output +
(from panel)
RS-422 Output –
(from panel)
Audio Output +
(from panel)
Audio Input +
(into panel)
Audio Input –
(into panel)
Audio Output –
(from panel)
RS-422 Input +
(into panel)
RS-422 Input –
(into panel)
Pair 1 Audio output from Matrix to panel
Pair 2 RS-422 data input from panel to Matrix
Pair 3 Audio input from panel to Matrix
Pair 4 RS-422 data output from Matrix to panel
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
Views from
front of
connectors