beautypg.com

Pair analog, Pair analog -13, Views from front of connectors – Clear-Com LMC-64 User Manual

Page 99

background image

Clear-Com
Eclipse Median Instruction Manual

7 - 1 3

4-Pair Analog

Four-pair analog wiring is done with shielded CAT5 RJ-45 cable.

• Pair 1 transmits analog audio from the matrix to the panel.

• Pair 2 transmits digital data from the panel back to the matrix.

• Pair 3 transmits audio from the panel to the matrix.

• Pair 4 transmits digital data from the matrix back to the panel

.

Figure 7-5: Wiring from the Matrix to an Analog Panel Using RJ-45

RJ-45 CONNECTOR
AT MATRIX PORT

RJ-45 CONNECTOR ON
PANEL OR INTERFACE

Matrix Frame RJ-45 Pin Numbers

Shielded category-5 cables wired pin-to-pin

Panel RJ-45 Pin Numbers

Pair 2

Pair 1

Pair 3

Pair 4

RS-422 Input +

(into Matrix)

RS-422 Input –

(into Matrix)

Audio Input +

(into Matrix)

Audio Output +

(from Matrix)

Audio Output –

(from Matrix)

Audio Input –

(into Matrix)

RS-422 Output +

(from Matrix)

RS-422 Output –

(from Matrix)

1

2

3

5

6

7

1

2

6

7

8

4

3

4

5

8

RS-422 Output +

(from panel)

RS-422 Output –

(from panel)

Audio Output +

(from panel)

Audio Input +

(into panel)

Audio Input –

(into panel)

Audio Output –

(from panel)

RS-422 Input +

(into panel)

RS-422 Input –

(into panel)

Pair 1 Audio output from Matrix to panel
Pair 2 RS-422 data input from panel to Matrix
Pair 3 Audio input from panel to Matrix
Pair 4 RS-422 data output from Matrix to panel

8 7 6 5 4 3 2 1

8 7 6 5 4 3 2 1

Views from
front of
connectors

This manual is related to the following products: