beautypg.com

Psu2 fail, Fan-on indicator, Power supply lights – Clear-Com LMC-64 User Manual

Page 38: Psu2 fail -18, Fan-on indicator -18, Power supply lights -18

background image

Clear-Com

Eclipse Median Instruction Manual

2 - 1 8

PSU2 Fail

When the second power supply unit is operating correctly, the red
PSU2 light is off, while the four green power supply lights (+12V, +5V,
+3.3V, -12V) are on continuously.

When a DC output or AC input to the second power supply drops too
low, the red PSU2 light switches on. The amber (HITRON) or red
(Power-One) light on the power supply unit itself also switches on to
indicate the same condition. One of the green power supply lights may
then switch off to help indicate the source of the trouble.

Note that the PSU2 fail light only works if the second power supply is
plugged into the matrix’s midplane from inside the matrix.

Note: A temperature sensor inside the power supply senses if the

power supply overheats, and switches on the second matrix
cooling fan. The red “Temp” light switches on to indicate
that the active CPU card, not a power supply, has
overheated.

Fan-On Indicator

Two fans deliver forced air cooling to the matrix’s power supplies. The
primary fan runs continuously. If a temperature exceeding a threshold
is detected in a power supply and extra cooling is required, a second
fan switches on to increase the air flow. The “fan-on” alarm light
illuminates red to indicate that the second fan is on.

POWER SUPPLY LIGHTS

The green power-supply lights illuminate to indicate that the power
supplies are receiving +12 V, –12 V, +5 V, and 3.3 V power.

You can precisely locate a

port with its row and column

numbers as shown in Figure

2-7.