Rs-232 connector, Alarm i/o connector, Connecting to general-purpose outputs (“gp out”) – Clear-Com LMC-64 User Manual
Page 42: Rs-232 connector -22, Alarm i/o connector -22, Connecting to general-purpose out- puts (“gp out”)
Clear-Com
Eclipse Median Instruction Manual
2 - 2 2
Note: If this port is used a ferrite must be added to the socket end
of each cable. A suitable ferrite is Würth Electronik part:
74271132.
RS-232 CONNECTOR
The female 9-pin D-type socket labeled “RS-232” connects the CPU
card to an external computer.
Note: A shielded cable should be used.
ALARM I/O CONNECTOR
The female 9-pin D-type socket labeled “Alarm I/O” connects the
Eclipse matrix to an external alarm indicator, such as a light or buzzer
and/or to an external alarm source.
Note: A shielded cable should be used.
CONNECTING TO GENERAL-PURPOSE OUT-
PUTS (“GP OUT”)
The male 25-pin D-type socket labeled “GP OUT” connects the CPU
card to eight general purpose outputs (GPOs). General-purpose
outputs are single-pole double-throw relays with contact ratings of 30
VDC (volts direct current) at 1 ampere.
A general purpose output or “relay” is a switch that is controlled
remotely. The relay is programmed in ECS to close a contact
whenever an intercom panel key is pressed. When the contact is
closed, it completes an electronic circuit’s signal path so that a remote
device, such as a light, is powered.
A GPO can be programmed to mute a speaker, to turn on an applause
light, to turn on a door lock, or to perform a variety of other functions.
For example, to get the attention of a panel operator working in a
high-noise environment such as a control booth, a relay can be
prgrammed to switch on a light at operator panel each time an
incoming call is received, to ensure that the call is not missed.
Note: If the GP-OUT port is used on a Median matrix fitted with
HITRON power supplies (part 740134Z) the following filter
must be fitted between the PROC-RCC socket and the cable:
CINCH FA-25PS/1-LF 25W D-type in-line 1000pF filter
(UK supplier: Farnell 111-4108)
If the Median matrix is equipped with Power-One power
supplies (part 720379Z) this filter should not be fitted. If this
filter is already fitted to an Median matrix and the power