beautypg.com

Single-pair digital, Single-pair digital -14 – Clear-Com LMC-64 User Manual

Page 100

background image

Clear-Com

Eclipse Median Instruction Manual

7 - 1 4

Single-Pair Digital

Single-pair digital wiring is accomplished with double-shielded 24
AWG conductor CAT-6E enhanced STP cable. Pair 1 transmits and
receives multiplexed digital and analog between the matrix and the
panel.

Note: Ensure that the “select” switch on the panel rear is in the

correct position for the intended use.

Figure 7-6: Wiring from the Matrix to a Digital Panel Using RJ-45

Note: This wiring diagram refers to the Digi-2 unit only.

Pair 2

Pair 1

Pair 3

Pair 4

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

Matrix Frame End

ATT-T568B (Modular Jumpers

Wired One to One)

Panel End

No Connection (NC)

No Connection (NC)

No Connection (NC)

Multiplexed Data/Audio

Multiplexed Data/Audio

No Connection (NC)

No Connection (NC)

No Connection (NC)

This manual is related to the following products: