beautypg.com

Troubleshooting data problems, General principles, Analog port card reset button – Clear-Com LMC-64 User Manual

Page 118: Troubleshooting data problems -6, General principles -6

background image

Clear-Com

Eclipse Median Instruction Manual

8 - 6

2. Check the power supplies’ alarm lights. If the alarm lights are

indicating a problem with the power supply, swap it out with a new
power supply.

• If this repairs the problem, the problem was in the power supply.

• If the problem persists even after the power supply has been

replaced, the problem is in the backplane. Send the matrix back
to Clear-Com for repair or replacement. In the meantime another
matrix can be substituted for the damaged one. Clear-Com may
ship a spare matrix to use while the damaged matrix is being
repaired depending on the support status. Please refer to the
warranty and support sections in this manual.

Problem: The power supply lights are out on both CPU
cards

The problem may be with power supplies, since both cards appear not
to be receiving power. Although less likely, the problem may be in the
matrix’s backplane connectors.

The following procedure may help to isolate where the trouble is
occurring:

Check the power supplies’ alarm lights. If the alarm lights are
indicating a problem with the power supply, swap it out with a new
power supply.

• If this repairs the problem, the problem was in the power supply.

• If the problem persists even after the power supply has been

replaced, the problem is in the backplane. Send the matrix back
to Clear-Com for repair or replacement. In the meantime another
matrix can be substituted for the damaged one. Clear-Com may
ship a spare matrix to use while the damaged matrix is being
repaired depending on the support status. Please refer to the
warranty and support sections in this manual.

TROUBLESHOOTING DATA PROBLEMS

General Principles

The other type of problem that can occur in the system is when data is
not flowing properly between the program software, the circuit cards,
and the attached panels and interfaces. A troubleshooting sequence in
this situation would be to first check cabling, then reset the card or
panel, then reset the entire system.

Analog Port Card Reset Button

Resetting the analog port card causes the configuration information for
the card and its attached devices to reload to the card from the CPU
card’s operational memory (located in its microprocessor’s RAM), thus
clearing up any corruption of data that may have occurred in the
analog port card’s microprocessor. The interface and all connected