Description
frequency proportional to the flow rate (f = KxQ, f is the frequency in Hz, K the proportionality factor, called K factor, in pulse/litre, which is
specific to each S030 fitting, and Q is the flow rate in l/s).
• The device 8072 detects the rotation of the oval gears of the S070 fitting. The oval gears generate a measuring signal with a frequency
proportional to the flow rate. The proportionality factor, called K factor, is specific to each S070 fitting.
5.3.
Available versions of the se32 electronic module
The order codes of the S030 or S070 fittings can be taken from the related data sheet: refer to the data sheets to select the fitting suited to
your application.
se32 version
supply
voltage
output
electrical connection
ul
order code
Threshold
detector
12-36 V DC Transistor, NPN
EN 175301-803 male fixed connector
no
436474
Threshold
detector
12-36 V DC Transistor, PNP
EN 175301-803 male fixed connector
no
434871
Threshold
detector
12-36 V DC Transistor, NPN
and PNP
Male 5-pin M12 fixed connector
no
436473
yes
553431
Threshold
detector
12-36 V DC Relay
Male 5-pin M12 and male EN 175301-803 fixed connectors
no
436475
Flowmeter
12-36 V DC 4-20 mA + Relay
Male 8-pin M12 and male EN 175301-803 fixed connectors
no
560547
Flowmeter
12-36 V DC 4-20 mA + Relay
Male 5-pin M12 and male EN 175301-803 fixed connectors
no
560402
Flowmeter
12-36 V DC 4-20 mA
Male 5-pin M12 fixed connector
no
560403