Electrical data, Fig. 7), Fig. 8) – Burkert Type 8072 User Manual
Page 14: English
12
Technicaldata
1
9
2
3
4
5
6
7
8
10
4
8
20
-4
-8
-12
-16
-20
16
12
Fluid velocity in m/s
Max error %
Measuring
error
-
%
of
the
measurement
with a Teach-in procedure
With standard K factor of
the S030 fitting
Fig. 7:
Accuracy of the measurements made by a 8032, when
using or not the Teach-in feature.
These values were determined in the following reference conditions:
medium = water, water and ambient temperatures 20 °C, min. upstream and
downstream distances respected, appropriate pipe dimensions
10
9
8
7
6
5
4
3
2
1
0
-15
0
+20 +40
+60
+80 +100
A
PVDF
PVDF (PN10)
PVC (PN10)
PP (PN10)
11
12
13
14
15
16
PVC + PP
P [bar]
T [°C]
Metal (PN16)
Fig. 8:
Fluid temperature / pressure dependency of the 8032,
depending on the material the S030 fitting is made of
6.3.3. electrical data
Table 1:
Electrical data for threshold detectors
Installation class (over-
voltage class)
2
Supply voltage
12-36 V DC
Dielectric strength
2300 V AC
English
Technical data