General technical data, Mechanical data – Burkert Type 8072 User Manual
Page 11

9
Technicaldata
Acc. to the 97/23/CE pressure directive, the fitting S030 can only
be used in the following cases (depending on max. pressure, pipe
diameter and fluid):
type of fluid
conditions
Fluid group 1, par. 1.3.a
only DN ≤ 25
Fluid group 2 par. 1.3.a
DN ≤ 32
or DN > 32 and PNxDN ≤ 1000
Fluid group 1 par. 1.3.b
PNxDN ≤ 2000
Fluid group 2 par. 1.3.b
DN ≤ 200
The UL device, with order code 553431, for the United States of
America and Canada complies with the following standards:
• UL 61010-1
• CAN/CSA-C22.2 n° 61010-1.
6.3.
General technical data
6.3.1. mechanical data
parts not exposed to the
fluid
material
Housing, cover
Fibre glass reinforced polycarbonate
Fixed connectors
PA
Front panel
Polyester
parts not exposed to the
fluid
material
Screws
Stainless steel
O-ring seals
FKM as standard (EDPM optional)
Dn
h with s070 fitting
H
15
85
25
100
40
117
50
135
80
175
100
176
Fig. 2:
Dimension H [mm] of the 8072 depending on the S070
fitting diameter