beautypg.com

Changing the electrical function module, Changing the electrical function module 8.4 – Burkert Type 8644 User Manual

Page 59

background image

59

Installation

NoTE!

Alternative for large valve blocks:

Remove the predecessor module,

Snap the valve block onto the standard rail,

Slide the block to its final position,

Snap on the predecessor module again.

changing the electrical function module

8.4.

DANgEr!

danger – high pressure!

Before dismounting pneumatic lines and valves, turn off the pressure and vent the lines.

risk of short-circuit!

Do not insert any foreign objects into the base module (24 V supply bus)!

The function module is a component of the electronic base module. It can be replaced in consideration of the points
listed below:

Depressurize AirLINE system.

Using a screwdriver, loosen the fastening screws of the valves.

Remove valve from the valve plug.

Flange seal and O-ring (3/2-Way valve) must not be soiled.

Detach function module above rear catch mechanism and remove vertically without tilting it from the distributor

module (backplane bus).

Place new function module vertically on the distributor module (backplane bus) and press down until it clicks

into position.

Connect valve, with the cleanly inserted flange seals / O-rings, to the valve slot and tighten the screws

according to the following assembly diagram (see

Figure 32:Tightening the screws).

20 Ncm

20 Ncm 30 Ncm

30 Ncm

Figure 32:

Tightening the screws

Typ 8644

deutsch