Structure and function of the modules

On the electronic base module the digital outputs are switched where the valves are located. Depending on the
operating principle of the valve, these outputs switch the internal P channel to the working connections (outputs)
of the pneumatic base modules.

NoTE!

Do not change attached valves until AirLINE has been depressurized.

If a P shut-off is used, the valves can also be changed under pressure.

Variants

Thanks to the modular design of the valve disc, there are several variants:

types

pneumatic/electronic

Mp11 / Me02

Mp12 / Me03

Add-on dimension

11 mm

16.5 mm

Valve types

6524
6525

0460

6526
6527
0461

Number of valve locations on
electronic base module

2-fold

8-fold

2-fold

3-fold*

4-fold

Number of valve locations on
pneumatic base module

2-fold


8-fold

2-fold

3-fold*

4-fold

Connection version
(Pneumatic base module)

D6
D4

D1/4“

M5
M7

D8

G1/8"

NPT 1/8"

D4**

D1/4“**

D6**

M5**
M7**

Non-return valves (optional)

without non-return valve

non-return valve in R channel

non-return valve in R+S channel

P shut-off (optional)

with P shut-off***

not available

* Overall width of electronic/pneumatic base module = 33 mm, with 3 slots for 10 mm valves
** Special design 3-fold, 10 mm valves
*** Available for certain valve types and with function restriction only. See also

6.2.Technical data of the entire

system and 7.4.Pneumatic base module.