beautypg.com

3 installation – Burkert Type 2731 User Manual

Page 17

background image

Control function A pressurize the lower pilot air port with com-
pressed air (5 bar): valve opens.

Remove actuator with diaphragm by loosening the body screws.

Actuator

Body screws

Valve body

Lower pilot air port

Upper pilot air port

Diaphragm

Fig. 12: Installation

7.3

installation

WarNiNg!

risk of injury from improper installation!
Non-observance of the tightening torque is dangerous as the
device may be damaged.

Observe the tightening torque (see “Tab. 8: Tightening torques

for diaphragms”).

7.3.1 installation of the valve body

Welded bodies

Weld valve body in pipeline system.

Other body versions

Connect body to pipeline.

7.3.2 installation of the actuator (welded

body)

installation for actuator with control function a:

NoTiCe!

damage to the diaphragm or the seat contour!

▶ When installing the actuator, ensure that the valve is in open

position.

Control function A pressurize the lower pilot air port with com-
pressed air (5 bar): valve opens.

Lightly cross-tighten the body screws until the diaphragm is
between the body and actuator.
do not tighten the screws yet.

Actuate the diaphragm control valve twice.

Without pressurization tighten the body screws to the permitted
tightening torque (see following table “Tab. 8: Tightening torques
for diaphragms”
).

17

Installation

english

Type 2730 / 2731 DN 65-100