beautypg.com

7 technical data, 7technical data, 2 function – Burkert Type 2105 User Manual

Page 8: 1 conformity, 2 standards, 3 type label, English

background image

8

Technical data

6.2 function

Spring force (CFA) or pneumatic pilot pressure (CFB and CFI)
generates the closing force on the diaphragm pressure piece. The
force is transferred via a spindle which is connected to the actuator
piston.

6.2.1

control functions (cf)

Warning!

for control function I – danger if pilot pressure fails!
For control function I (CFI) control and resetting occur pneumatically.
If the pressure fails, no defined position is reached.

▶ To ensure a controlled restart, first pressurize the product with

pilot pressure, then switch on the medium.

CFA

P

A

Closed by spring force in rest position.

CFB

P

A

Opened by spring force in rest position.

CFI

P

A

Actuating function via reciprocal

pressurization.

7

Technical DaTa

Warning!

risk of injury from high pressure!
Important product-specific technical specifications are indicated
on the type label.

▶ Observe permitted pressure range on the type label of the product.

7.1 conformity

Type 2103, 2104 and 2105 conforms with the EC Directives according
to the EC Declaration of Conformity.

7.2 standards

The applied standards, which verify conformity with the EC Direc-
tives, can be found on the EC-Type Examination Certificate and / or
the EC Declaration of Conformity.

7.3 Type label

Example:

00175139

2103 A 20M PTFE VS

Tamb 0°C - +60°C

Tmed xxx°C - +130°C

Pilot 4,8-10bar

Pmed 10,0bar

Da=26,9 s=1,6

W3ZLT

CE

Fig. 4:

Example of type label

english

Type 2103, 2104, 2105

This manual is related to the following products: