beautypg.com

Burkert Type 0641 User Manual

Page 9

background image

9

Application Conditions for the units

5.1.3 Type of explosion protection

Version with built-in rubber sheathed cable (A):
Ex mb IIC T4 or T5

Version with terminal box (L and K):
Ex e mb IIC T4 or T5 to EN 60079-0, 60079-7, 60079-18

5.1.4 Dimensions

Connection type Length (mm)

Width (mm)

Height (mm)

Electrical
connection A

96

32

59

Electrical
connections L&K

112

60

113

5.1.5 Type of protection

IP65 to EN 60529 (DIN VDE 0470 Part 1)

5.1.6 Individual and block assembly

The solenoids coil type 64.-....-...-. / 65.-....-...-. are suitable for indi-
vidual and block assembly.

5.1.7 Operational temperature range

Please note the operational temperature range listed for each type in
the Electrical Data!

5.1.8 Maximum permissible ambient

temperature range

Please observe the maximum permissible ambient temperature range
given under Operating conditions of the coils for each type!

Version

Installation

Maximum permissible

ambient temperature range

64.-....-...-.

Individual assembly

- 40 °C ... + 60 °C

Block assembly

- 40 °C ... + 45 °C

65.-....-...-.

Individual assembly

- 40 °C ... + 50 °C

Block assembly

- 40 °C ... + 40 °C

5.1.9 Special version Solenoid Type

655-1.5.-...-.

Rated voltage UC

12 ... 240 V

Max. permissible voltage tolerance

± 20 %

Rated current

0.42 ... 0.025 A

Limiting power consumption in
equilibrium

5 W

Temperature class

T5

Ambient temperature

- 40 °C ... + 40 °C

Permissible installation

individual assembly only

With these devices, a voltage tolerance of ± 20 % is permissible.
They may only be installed in individual assembly.

english

PTB 02 ATEX 2094 X