11

Technical Data

6

TECHNICAL DATA

DANGER!

Risk of explosion!
Exceeding the technical data indicated on the rating plate
increases the explosion risk!

▶ Never exceed the technical data indicated on the rating plate!

Sicherung/Fuse
... A

IEC Ex PTB 09.0064X

Ex e mb IIC T4 Gb

IEC Ex PTB 09.0

064X

Ex e mb IIC T4 Gb

WARNING -
POTENTIAL ELECTROSTATIC
CHARGING HAZARD -
SEE INSTRUCTIONS

WARNING

-

POTENTIAL

ELECTROST

ATIC

CHARGING

HAZARD

-

SEE

INSTRUCTIONS

1
2
3
4
5
6

ATEX

certification No.

Approval mark

Coil type
Voltage

(±10 %),

power rating

Serial no.

,

CE designation

Ident. no. / date of production

Example

1

2

3

4

5
6

PTB 02 ATEX 2094 X

II 2 G Ex e mb IIC T4 Gb

643-4104

24V AC/DC 7W
S/N 1081

0102

00999999

W1XMG

PTB 02 ATEX 2094

X

II 2 G Ex e mb IIC T4 Gb

643-4104

24V AC/DC 7W

S/N 1081

0102

00999999

W1XMG

Fuse/contactor

... A

Approval mark
IEC Ex

certification No.

6.1 Electrical data

Type

64.-....-...-.

65.-....-...-.

Temperature class

T4

T5

Type of current

universal

universal

Rated voltage

12 ... 240 V

12 ... 240 V

Rated current

0.58 ... 0.034 A

0.42 ... 0.025 A

Holding power

7 W

5 W

english

PTB 02 ATEX 2094 X