Installation and Commissioning

DANGER!

High voltage!
Acute risk of injury from hazardous structure-borne voltage!
Risk of damage to the device due to short circuit!

▶ Work on the electrical system may only be carried out by quali-

fied electricians.

▶ Before starting work, switch off the power supply and secure to

prevent it being switched on again!

▶ Live terminals in the terminal box can cause electric shock, short

circuit or explosion. Switch off the power supply before open-

ing the terminal box.

▶ The connecting cables to the electromagnets must be secure,

and be laid so that they are adequately protected from mechani-

cal damage.

▶ Observe the applicable accident prevention and safety regula-

tions for electrical devices!

WARNING!

Pressurised system!
Interventions in the pneumatic system represent an acute risk of
injury.

▶ Work on the pneumatic system may only be carried out by quali-

fied and instructed personnel using appropriate tools.

▶ First switch off pressure before disconnecting lines and valves.

▶ Observe the flow direction during installation!

▶ Observe the applicable accident prevention and safety regula-

tions for pneumatic systems!

7.1 Assembly

NOTES!

Installation in any position.
Preferably with solenoid system mounted at the top.
The devices are suitable for individual and block assembly..

Clean the pipe runs.

Connect a dirt-trap (strainer) upstream. Note the direction of flow!

Seal PTFE.

Screwing on the pipe run. Note the direction of flow!

Installation / Dismounting.

NOTES!

Always connect the earth conductor!
Note for units with connecting cable: The connecting cable and the
coil are moduled together. They must not be dismantled!

Make electrical connections.

7.2 Commissioning

Before commissioning, ensure that
• the device has been correctly installed,
• the connections have been correctly made,
• the device is not damaged,
• all bolts are securely tightened.

english

PTB 02 ATEX 2094 X