beautypg.com

Brooks, Model 5851 i – Brooks Instrument 5851i User Manual

Page 43

background image

4-15

Installation and Operation Manual
X-TMF-5851i-MFC-eng
Part Number: 541B109AAG
September, 2009

Brooks

®

Model 5851

i

Section 4 Maintenance

& Troubleshooting

Flow Rate: 100 slpm
Outlet Pressure: 30 psig
Inlet Pressure: 50 psig

1. Determine Nitrogen equivalent flow rate (refer to Table 4-3).

Q

Nitrogen

=

Nitrogen equivalent flow rate (sccm)

Q

gas

=

Desired flow rate of the gas (sccm)

D

Nitrogen

=

Density of Nitrogen at 70°F

D

gas

=

Density of the gas (taken at customer
temperature)

SG

gas

=

Specific gravity of the gas (taken at customer
temperature)

Refer to Table 4-3 for specific gravities.
Example:

In order to calculate the orifice conversion factor when using a gas mixture,
the following formula must be used:

Where P1

=

percentage by volume of gas 1

P2

=

percentage by volume of gas 2

Pn

=

percentage by volume of gas n

Example: Find the Nitrogen equivalent flow for 20 slpm of a 20%

Helium and 80% Chlorine gas mixture.