beautypg.com

Installation and operation manual – Brooks Instrument QMBM User Manual

Page 20

background image

QmB Series IP40, IP66, IP66XP

Section 1 Introduction

1-8

Installation and Operation Manual

X-CM-QmB-eng

Part Number: 541B029AAG

June, 2011

Certifications and Approvals

IP40 Series

Non Incendive/ Non Sparking
United States and Canada- UL Recognized E73889, Vol. 3, Sect. 3.

Non Incendive , Class I, Division 2, Groups A, B, C and D; T4
Per UL 1604, UL 508 and CSA 22.2 No. 213 1987; C22.2 No. 14-M91

Ex nC IIC T4
Per CSA E79-15

Class I, Zone 2, AEx nC IIC T4
Per ANSI/UL 60079-15

Ambient Temperature: 0

o

C to 65

o

C

Enclosure: Type 1/ IP40

Europe - KEMA 04ATEX1241 X

II 3 G EEx nA II T4
Per EN 60079-15: 2003

Ambient Temperature: 0

o

C to 65

o

C

Enclosure: IP40
The modules shall be installed in a suitable enclosure providing a degree of at least IP54 according to
EN60529, taking into account the environmental conditions under which the equipment will be used.

IP66 Series

Non Incendive/ Non Sparking
United States and Canada- UL Recognized E73889, Vol. 1, Sect. 26. (conduit entry)
United States and Canada Recognized, UL E73889, Vol. 3, Sect. 3. (cable gland entry)

Non Incendive , Class I, Division 2, Groups A, B, C and D;
Dust Ignition Proof, Class II, Division 2, Groups F and G; Suitable for Class III, Division 2; T4
Per UL 1604, UL 508 and CSA 22.2 N0. 213 1987; C22.2 No. 14-M91

Ex nC IIC T4
Per CSA E79-15

Class I, Zone 2, AEx nC IIC T4
Per ANSI/UL 60079-15

Ambient Temperature: 0

o

C to 65

o

C

Enclosure: Type 4X/ IP66

This manual is related to the following products: