Figure 3 xlut 45 d (also valid for xlut 90 d) – FlexLink X65 Функциональные модули Руководство пользователя User Manual
Page 19

Initiators
Actuators
Interfaces
B1 Pre-stop highway
B2 and B3 sensing pallet route
B4 and B5 position of diverter arm
B6 RFID head
A1 Pre-stop. Single acting
A2 Arm. Double acting
B1-B5 M12-connector, 3-pin
B6 RFID, 4-pin (ASI)
A1 Ø 6 mm pneumatic hose
A2 Ø 6 mm pneumatic hose
B3
B4
B5
B2
A2
A1
B1
B6
Functions
Created by EBCCW 00:06
11
8050179
Figure 3
XLUT 45 D (also valid for XLUT 90 D)
Principle of operation
Diverting pallet to satellite:
A pallet on Highway is approaching. Sensor B1 is activated which actuates
stop A1 which stops the pallet, if function is occupied.
Sensor B2 and B3 supervise the function area. If both sensors gives low
signal the area is empty.
Straight passing through:
A pallet on Highway is approaching. The pallet activates sensor B1 which
actuates stop A1 which stops the pallet if function is occupied.
Sensor B2 and B3 supervise the function area. If both sensors gives low
signal the area is empty.