Initiators

Actuators

Interfaces

B1 Pre-stop highway
B2 and B3 sensing pallet route
B4 and B5 position of diverter arm
B6 RFID head

A1 Pre-stop. Single acting
A2 Arm. Double acting

B1-B5 M12-connector, 3-pin
B6 RFID, 4-pin (ASI)
A1 Ø 6 mm pneumatic hose
A2 Ø 6 mm pneumatic hose

B3

B4

B5

B2

A2

A1

B1

B6

Functions

Created by EBCCW 00:06

11

8050179

Figure 3

XLUT 45 D (also valid for XLUT 90 D)

Principle of operation

Diverting pallet to satellite:

A pallet on Highway is approaching. Sensor B1 is activated which actuates

stop A1 which stops the pallet, if function is occupied.
Sensor B2 and B3 supervise the function area. If both sensors gives low
signal the area is empty.

Straight passing through:

A pallet on Highway is approaching. The pallet activates sensor B1 which

actuates stop A1 which stops the pallet if function is occupied.
Sensor B2 and B3 supervise the function area. If both sensors gives low
signal the area is empty.