Advantech PCE-5120 User Manual
Page 102

PCE-5120 User Manual
86
Inc
dx
Mov al,10
Out dx,al
;-----------------------------------------------------------
Dec dx
; lock W83627HF
Mov al,0aah
Out dx,al
2.
Enable watchdog timer and set 5 minutes as timeout interval
;-----------------------------------------------------------
Mov dx,2eh ; unlock W83627HF
Mov al,87h
Out dx,al
Out dx,al
;-----------------------------------------------------------
Mov al,07h ; Select registers of watchdog timer
Out dx,al
Inc
dx
Mov al,08h
Out dx,al
;-----------------------------------------------------------
Dec dx
; Enable the function of watchdog timer
Mov al,30h
Out dx,al
Inc
dx
Mov al,01h
Out dx,al
;-----------------------------------------------------------
Dec dx
; Set minute as counting unit
Mov al,0f5h
Out dx,al
Inc
dx